Be.Smart T4I
(EN) T4I
(EN) T4I
  • ℹ️What is T4I?
  • ⚙️System Requirements
  • 🔑Installation & Activation Guide
  • 🏁Quick Start Guide
    • Product Language
    • Icon Layout for Your Optimal Performance 🌟
    • Get Help Easily
    • Automatize Your iProperties Workflows
      • Automatic iProperties
      • iProperties Synchronization
      • iProperties Dialogue Windows
    • Easy Document Publishing
    • Protect Your T4I Settings
    • Useful Links
  • 🆕What's New🌟
    • Version 26.5.0.0🌟
    • Version 26.4.1.1
    • Version 26.4.1.0
    • Version 26.4.0.0
    • Version 26.3.1.0
    • Version 26.3.0.0
    • Version 26.2.0.0
    • Version 26.1.1.0
    • Version 26.1.0.0
  • 📘Commands Overview
    • Structure of Commands in the Inventor UI
    • Be.Smart T4I
      • Edit Settings
        • Auto iProperties
          • Automatic update of iProperties
          • Synchronization of iProperties
        • QR code tools
        • Properties Dialog
        • iLogic
        • Publisher
          • Saving files using relative paths
        • Quantities
        • Display Name
        • Other tools
          • Save and return to sketch
        • Helpdesk
        • General
          • Configuration settings🌟
          • Language settings
      • Layout
      • Advanced settings
        • Validate Document On Save
      • Edit iProperties
      • iLogic commands
      • Export settings
      • About
    • Helpdesk
      • Screenshot Inventor
      • Screenshot Desktop
      • Delete helpdesk
      • Open helpdesk
      • Helpdesk web
      • System info
      • Zip
      • Open WeTransfer
      • Start TeamViewer
      • Help
    • Model
      • Hide all
      • Sync camera
      • Model player
      • Apply display name
      • To origin
      • Push parameters
      • Publish iMates
      • Rename nodes
    • Sketch
      • As construction
      • Project origin
    • iLogic Samples
      • Installed printers
      • Quick properties
      • Center text
      • Export PDF
      • Quick print
      • Save TS
      • Units Converter
    • Publish
      • Export DWG
      • Export DXF
      • Export STEP
      • Export PDF
    • BOM
      • Sync
      • Sync 2
      • Update
      • Copy
      • Push Qty
      • Extract BOM
    • iProperties Transfer
      • Model to Drawing
      • Drawing to Model
    • Annotations
      • QR Code
      • Data Matrix
      • Align hatching
      • Diameter
      • Diameter H7
      • Thread M
      • Chamfer
      • Tolerance
      • Parentheses
      • 1/2
      • Reset
      • Center text
    • Commands outside the Inventor ribbon
      • Open Location
      • UCS Visibility
    • 💡Selected Topics
      • T4I configuration backup and deployment
    • ⚗️Be.Smart T4I Labs
      • 📧Send Us Feedback!
      • Fixed Workpoint
      • Colorizer
      • First-view Model to Drawing Property Sync
      • Quick Command Search
      • Time Tracker
Powered by GitBook
On this page
  • Backup Your Settings
  • Restore Your Settings
  • Additional Backup Information
  • Advanced Backup
  • Advanced Restoration

Was this helpful?

  1. Quick Start Guide

Protect Your T4I Settings

T4I Settings Backup and Restoration

Last updated 7 months ago

Was this helpful?

To keep your workflows uninterrupted, T4I settings can be easily backed up and restored if needed.

By default, the T4I settings are stored in the Windows registry. When modifying the registry, always proceed with caution.

Backup Your Settings

  1. Go to the Be.Smart T4I (ribbon) -> Be.Smart T4I (panel) -> Export settings.

  2. In the “Save as” window, select “Save as type” Registry file (*.reg), and save the file.

Restore Your Settings

  1. Make sure the Autodesk Inventor is not running.

  2. Double-click the *.reg file you created as a backup.

  3. Confirm changes to the registry.

  4. Restart the Inventor.

Additional Backup Information

Using the registry file as a backup method is recommended by default for individual users. The registry method preserves also the user’s individual settings like the application language, splash screen visibility, or the settings configuration type (registry/XML). In corporate environments, where the settings should be shared among many users, it may be undesirable to distribute purely individual user settings to other users. Therefore, the XML file backup can be used.

Advanced Backup

  1. Go to the Be.Smart T4I (ribbon) -> Be.Smart T4I (panel) -> Export settings.

  2. In the “Save as” window, select “Save as type” XML file (*.xml), and save the file. Two files with the same name will be created: the XML file containing the general T4I settings, and the REG file containing the individual user settings.

Because the two files are created during the export, only the XML file can be used to deploy the general T4I settings among other users, but the individual user settings remain preserved in the REG file.

Advanced Restoration

To restore the T4I settings from the XML file:

  1. Go to the Be.Smart T4I (ribbon) -> Be.Smart T4I (panel) -> Edit settings -> General tab.

  2. Select Xml from the “Configuration type” drop-down menu.

  3. In the “Configuration file name” field, browse for the XML file.

  4. Click the OK button and restart the Inventor or T4I addon.

🏁